Items: 0  My Cart $0.00

    Opus 20 Datalogger for Temp, RH, CO2

    Item No: 8120-20

    See all items from Lufft Instruments
    Product Description

    Opus 20 Datalogger for Temp, RH, CO2
    Lufft offers a variety of models with internal or external sensors for recording humidity, temperature, pressure and CO2.

    Model 8120-20 TCO records Temperature, Relative Humidity and CO2.

    For climate monitoring and recording in buildings, air conditioning units, laboratory, cleanroom, storerooms and museums, alarm indication (current or historical since the last data transmission), conversion of the display from %RH to absolute humidity or dewpoint with SmartGraph professional software.

    A high level of CO2 in the air within a room causes headaches, tiredness and lack of concentration. The regulation on CO2 concentration was established in order to evaluate IAQ (Indoor Air Quality). As a guideline for school rooms in the USA the limit of 1,000 ppm applies; for workplaces the occupational exposure limit is 5,000 ppm.

    • Economically priced
    • Comes with SmartGraph 3 software, connecting cable and manual— everything needed to record and download 
    • NIST Certification and antitheft wall-mounting device optional 
    • POE (power over ethernet), USB, RS232 options on each model

    Specifications and additional product information
    OPUS 20 Temperature/RH/ CO2 Item# 8120-20  
    OPUS 20 Temperature/ RH/
    CO2 POE
    Item# 8120-21 
    Dimensions 6½" x 3" x 1¼" (166mm x 78mm x 32mm)
    Measuring interval 10/30s, 1/10/12/15/30min, 1/3/6/12/24h
    Construction Plastic housing
    Operating time with battery > 1 year
    Data storage 16 MB, 3,200,000 measured values
    LC-Display 3½" x 2½" (90 x 64mm)
    Weight 8 oz. (250g)
    Included in delivery PC-Windows™- Software SmartGraph 3
    for graphic and numerical representation
    of measured values / instruction manual
    / data cable / battery
    Interface USB, LAN
    Storage rate 1/10/12/15/30min, 1/3/6/12/24h
    Power supply 4 x LRG AA Mignon, USB, (POE opt.)
    Temperature
    Principle NTC
    Measuring range -4 to 144°F (-20...50°C)
    Accuracy ±0.3°C (0...40°C), otherwise 0.5°C
    Resolution 0.1°C
    Relative humidity
    Principle capacitive
    Measuring range 10..95% RH
    Accuracy ±2% RH
    Resolution 0.5% RH
    CO2
    Principle NDIR
    Measuring range 0...5000 ppm
    Accuracy ±50 ppm + 3 measured values at 20°C
    1,013mbar
    Resolution 1 ppm
    Long Term stability 20 ppm/s
    $1,182.00
        